leer
English   German
leer

Bader GmbH

Siemensstrasse 21
D- 71691 Freiberg
Tel: 07141/ 68877-0
Fax: 07141/ 68877-22
www.badergmbh.de

CAN- Bus- Systems

The CAN-Bus is a typ of network, which is used mainly in the automotive engineering
He combines different control units, called nodes, to exchange informations.
The nodes are installed in the near of the sensors and actors.
The BADER air condicioning systems are built according to this principle.

The following systems serve komplex air conditioning tasks in one- deck and double- decker buses
Concerning the design and implemented software these are customer specified solutions.
They vary depending of the aggregates to be controlled and the "climatisation-philosophy" for
the different types of buses.
With these systems BADER delievers inportant manufacturers like MAN, Neoplan, Viseon.

System 0490 (MAN)

   
  control panel 0490

Handling of the complete bus climatisation.
controlling of the frontbox
measuring the outdoor temperature
     
  water station node 1362

controlling of pumps,
water valves,
auxiliary heating,
air condicioner
     
 

roof channel node 1390,
right and left side

controlling evaporator blower, roof channel blower,
measuring roof channel temperature,
room temperature

 

 

   

System 0495 (Neoplan)

  "Skyliner" double- decker bus
 

control panel 0492

Handling of the complete bus climatisation.
controlling of the frontbox
measuring the outdoor temperature

     
  water station node 1362

controlling of pumps, water valves,
auxiliary heating,
air condicioner

     
  2x roof channel node 1390,
right and left side

controlling evaporator blower, roof channel blower,
measuring roof channel temperature,
room temperature

 

 

   

System 0590

  "Universal controller"
 

control panel 0590

Handling of the complete bus climatisation.
controlling of the frontbox
measuring the outdoor temperature

     
  water station node 1362

controlling of pumps, water valves,
auxiliary heating,
air condicioner

     
  3x roof channel node 1390,
right, left, upper deck

controlling evaporator blower, roof channel blower,
measuring roof channel temperature,
room temperature

 

 

   

system 0494

   
  control panel 0494

Handling of the complete bus climatisation.
controlling of the frontbox
measuring the outdoor temperature

     
 

water station node 1362

controlling of pumps, water valves,
auxiliary heating,
air condicioner

     
 

2x roof channel node 1390,
right and left side

controlling evaporator blower, roof channel blower,
measuring roof channel temperature,
room temperature

 

 

   

System 0323 ( universal )

   
  controller 0323

This system can be used in different
applications, e.g.
climate conrol of driver cabins,
mini busses.
Can be extended with
CAN- node 1393
     
  node 1393

system extension for controller 0323.
Controlling of blowers, valves,
temperature measuring, e.g.
room, roof channel.